| Assessment Year | 2001 |
|---|---|
| Principal Product | Chemical Analyses |
| NAICS |
n/a
|
| SIC | 3829: Measuring and Controlling Devices, Not Elsewhere Classified |
| Sales Range | $5 M to 10M |
| # of Employees | 85 |
| Plant Area |
38,000
ft2
|
| Annual Production | 94,000
pieces
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Utah |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $58,921 | 2,244,480 |
kWh
|
$0.026 |
| Electricity Demand | $37,912 | 4,584 |
kW-mo/yr
|
$8.27 |
| Electricity Fees | $6,319 | - |
|
- |
| Natural Gas | $45,540 | 7,642 |
MMBtu
|
$5.96 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $7,811 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $430 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,319 | $5,852 | n/a |
$1,450
47,824
kWh
|
$869
-
kW-mo/yr
|
- |
| 02 | 2.3212: Optimize plant power factor | $3,545 | $7,155 | n/a | - |
$3,545
-
kW-mo/yr
|
- |
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $430 | $430 |
$310
10,100
kWh
|
$120
-
kW-mo/yr
|
- | |
| 04 | 2.4314: Use synthetic lubricant | $564 | $400 |
$434
14,353
kWh
|
$130
-
kW-mo/yr
|
- | |
| 05 | 3.4115: Recover and reuse cooling water | $953 | $20 | - | - |
$953
-
gal
|
|
| TOTAL RECOMMENDED | $7,811 | $13,857 |
$2,194
72,277
kWh
|
$4,664
-
kW-mo/yr
|
$953
-
gal
|
||
| TOTAL IMPLEMENTED | $430 | $430 |
$310
10,100
kWh
|
$120
-
kW-mo/yr
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs