Assessment Year | 2001 |
---|---|
Principal Product | Metal Foundry |
NAICS |
n/a
|
SIC | 3320: |
Sales Range | $1 M to 5M |
# of Employees | 25 |
Plant Area |
25,000
ft2
|
Annual Production | 3,500
ton
|
Production Hrs. Annual | 4,590
hrs
|
Location (State) | Utah |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $122,859 | 2,403,470 |
kWh
|
$0.051 |
Electricity Demand | $30,784 | 22,282 |
kW-mo/yr
|
$1.38 |
Electricity Fees | $10,594 | - |
|
- |
Natural Gas | $96,880 | 23,926 |
MMBtu
|
$4.05 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,007 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,557 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,263 | $700 |
$2,347
54,238
kWh
|
$916
-
kW-mo/yr
|
- | - | |
02 | 2.2437: Recover waste heat from equipment | $1,384 | $950 | - | - |
$1,384
-
MMBtu
|
- | |
03 | 2.4133: Use most efficient type of electric motors | $1,066 | $1,066 |
$768
33,178
kWh
|
$298
-
kW-mo/yr
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $254 | $1,097 |
$108
4,650
kWh
|
$146
-
kW-mo/yr
|
- | - | |
05 | 4.821: Pay bills on time to avoid late fees | $1,040 | - | - | - | - | $1,040 | |
TOTAL RECOMMENDED | $7,007 | $3,813 |
$3,223
92,066
kWh
|
$1,360
-
kW-mo/yr
|
$1,384
-
MMBtu
|
$1,040 | ||
TOTAL IMPLEMENTED | $4,557 | $1,797 |
$2,455
58,888
kWh
|
$1,062
-
kW-mo/yr
|
- | $1,040 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs