Assessment Year | 2014 |
---|---|
Principal Product | stamped parts |
NAICS | 336370: Motor Vehicle Metal Stamping |
SIC | 3465: Automotive Stampings |
Sales Range | $100 M to 500M |
# of Employees | 340 |
Plant Area |
275,000
ft2
|
Annual Production | 44,946,173
pieces
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,029,690 | 17,924,880 |
kWh
|
$0.057 |
Electricity Demand | $6,597 | 2,639 |
kW-mo/yr
|
$2.50 |
Natural Gas | $576,075 | 115,215 |
MMBtu
|
$5.00 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $106,085 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $22,485 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $16,165 | $25,000 |
$14,920
259,910
kWh
|
$1,245
-
kW-mo/yr
|
- | |
02 | 2.7135: Install occupancy sensors | $6,320 | $4,800 |
$6,320
110,070
kWh
|
- | - | |
03 | 2.7244: Revise smoke cleanup from operations | $79,670 | $60,000 | - | - |
$79,670
-
MMBtu
|
|
04 | 2.7243: Improve air circulation with destratification fans / other methods | $3,930 | $6,000 | - | - |
$3,930
-
MMBtu
|
|
TOTAL RECOMMENDED | $106,085 | $95,800 |
$21,240
369,980
kWh
|
$1,245
-
kW-mo/yr
|
$83,600
-
MMBtu
|
||
TOTAL IMPLEMENTED | $22,485 | $29,800 |
$21,240
369,980
kWh
|
$1,245
-
kW-mo/yr
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs