Assessment Year | 2014 |
---|---|
Principal Product | Industrial Washers |
NAICS | 333318: Other Commercial and Service Industry Machinery Manufacturing |
SIC | 3559: Special Industry Machinery, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 79 |
Plant Area |
132,500
ft2
|
Annual Production | 100
pieces
|
Production Hrs. Annual | 3,120
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $199,636 | 1,753,885 |
kWh
|
$0.11 |
Natural Gas | $77,969 | 10,313 |
MMBtu
|
$7.56 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $119,298 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat | $58,763 | $200,000 |
$93,436
772,200
kWh
|
$(-34,673.0)
-
MMBtu
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $23,421 | $26,000 |
$23,421
207,286
kWh
|
- | |
03 | 2.1221: Replace obsolete burners with more efficient ones | $23,065 | $22,600 | - |
$23,065
-
MMBtu
|
|
04 | 2.7244: Revise smoke cleanup from operations | $14,049 | $6,000 | - |
$14,049
-
MMBtu
|
|
TOTAL RECOMMENDED | $119,298 | $254,600 |
$116,857
979,486
kWh
|
$2,441
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs