Assessment Year | 2013 |
---|---|
Principal Product | Gypsum Product Manufacturing |
NAICS | 327420: Gypsum Product Manufacturing |
SIC | 3275: Gypsum Products |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
50,000
ft2
|
Annual Production | 500,000
pieces
|
Production Hrs. Annual | 7,200
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $134,318 | 2,441,760 |
kWh
|
$0.055 |
Electricity Demand | $108,386 | 16,095 |
kW-mo/yr
|
$6.73 |
Natural Gas | $150,841 | 17,203 |
MMBtu
|
$8.77 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $102,220 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $56,632 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $23,008 | $21,730 |
$19,535
341,530
kWh
|
$3,473
-
kW-mo/yr
|
- | |
02 | 2.4237: Substitute compressed air cooling with water or air cooling | $19,439 | $2,500 |
$19,439
339,840
kWh
|
- | - | |
03 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $22,580 | $1,000 | - |
$22,580
-
kW-mo/yr
|
- | |
04 | 2.2437: Recover waste heat from equipment | $37,193 | $1,000 | - | - |
$37,193
-
MMBtu
|
|
TOTAL RECOMMENDED | $102,220 | $26,230 |
$38,974
681,370
kWh
|
$26,053
-
kW-mo/yr
|
$37,193
-
MMBtu
|
||
TOTAL IMPLEMENTED | $56,632 | $3,500 |
$19,439
339,840
kWh
|
- |
$37,193
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs