| Assessment Year | 2013 |
|---|---|
| Principal Product | Molded and Decorated Plastic Systems |
| NAICS | 326121: Unlaminated Plastics Profile Shape Manufacturing |
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 230 |
| Plant Area |
150,000
ft2
|
| Annual Production | 5,000,000
pieces
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $664,009 | 6,326,933 |
kWh
|
$0.10 |
| Electricity Demand | $17,874 | 15,244 |
kW-mo/yr
|
$1.17 |
| Natural Gas | $35,296 | 5,496 |
MMBtu
|
$6.42 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $34,072 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $16,762 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $13,129 | $17,000 |
$12,826
122,148
kWh
|
$303
-
kW-mo/yr
|
- | |
| 02 | 2.1221: Replace obsolete burners with more efficient ones | $13,400 | $12,000 |
$13,400
127,619
kWh
|
- | - | |
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,910 | $3,500 |
$3,910
37,240
kWh
|
- | - | |
| 04 | 2.2136: Install / repair insulation on steam lines | $1,407 | $1,500 |
$1,407
13,403
kWh
|
- | - | |
| 05 | 2.2437: Recover waste heat from equipment | $2,226 | $1,000 | - | - |
$2,226
-
MMBtu
|
|
| TOTAL RECOMMENDED | $34,072 | $35,000 |
$31,543
300,410
kWh
|
$303
-
kW-mo/yr
|
$2,226
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $16,762 | $19,500 |
$14,233
135,551
kWh
|
$303
-
kW-mo/yr
|
$2,226
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs