| Assessment Year | 2013 |
|---|---|
| Principal Product | Automotive Mechanical Testing |
| NAICS | 541380: Testing Laboratories |
| SIC | 8734: Testing Laboratories |
| Sales Range | $5 M to 10M |
| # of Employees | 40 |
| Plant Area |
26,000
ft2
|
| Annual Production | 100,000
pieces
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $204,377 | 1,533,945 |
kWh
|
$0.13 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $7,978 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $3,678 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7135: Install occupancy sensors | $454 | $175 |
$454
3,440
kWh
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,224 | $5,550 |
$3,224
24,427
kWh
|
|
| 03 | 3.4111: Use closed cycle process to minimize waste water production | $4,300 | $6,500 |
$4,300
33,000
kWh
|
|
| TOTAL RECOMMENDED | $7,978 | $12,225 |
$7,978
60,867
kWh
|
||
| TOTAL IMPLEMENTED | $3,678 | $5,725 |
$3,678
27,867
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs