Assessment Year | 2013 |
---|---|
Principal Product | Automotive Mechanical Testing |
NAICS | 541380: Testing Laboratories |
SIC | 8734: Testing Laboratories |
Sales Range | $5 M to 10M |
# of Employees | 40 |
Plant Area |
26,000
ft2
|
Annual Production | 100,000
pieces
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $204,377 | 1,533,945 |
kWh
|
$0.13 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,978 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,678 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7135: Install occupancy sensors | $454 | $175 |
$454
3,440
kWh
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,224 | $5,550 |
$3,224
24,427
kWh
|
|
03 | 3.4111: Use closed cycle process to minimize waste water production | $4,300 | $6,500 |
$4,300
33,000
kWh
|
|
TOTAL RECOMMENDED | $7,978 | $12,225 |
$7,978
60,867
kWh
|
||
TOTAL IMPLEMENTED | $3,678 | $5,725 |
$3,678
27,867
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs