Assessment Year | 2013 |
---|---|
Principal Product | Fiber Lasers |
NAICS | 541712: Research and Development in the Physical, Engineering, and Life Sciences (except Biotechnology) |
SIC | 8711: Engineering Services |
Sales Range | $10 M to 50M |
# of Employees | 70 |
Plant Area |
1,000,000
ft2
|
Annual Production | 100,000
lb
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $210,689 | 1,831,680 |
kWh
|
$0.12 |
Natural Gas | $10,141 | 1,727 |
MMBtu
|
$5.87 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $78,627 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $494 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.3416: Use combined cycle gas turbine generator sets with waste heat boilers connected to turbine exhaust | $75,276 | $110,000 | - |
$75,276
-
MMBtu
|
|
02 | 2.7135: Install occupancy sensors | $494 | $3,525 |
$494
4,289
kWh
|
- | |
03 | 2.2443: Re-use or recycle hot or cold process exhaust air | $2,857 | $4,000 | - |
$2,857
-
MMBtu
|
|
TOTAL RECOMMENDED | $78,627 | $117,525 |
$494
4,289
kWh
|
$78,133
-
MMBtu
|
||
TOTAL IMPLEMENTED | $494 | $3,525 |
$494
4,289
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs