ITAC Assessment: UM0322
ITAC logo
ITAC Assessment: UM0322
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2007
Principal Product Recycled Industrial Oil and Metalworking Products
NAICS 324191: Petroleum Lubricating Oil and Grease Manufacturing
SIC 2992: Lubricating Oils and Greases
Sales Range $10
M
to 50
M
# of Employees 25
Plant Area 3,500
ft2
Annual Production 5,000
Tgal
Production Hrs. Annual 8,736
hrs
Location (State) Michigan

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $158,202 1,546,186
kWh
Electricity Fees $493 -
Natural Gas $295,886 47,200
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $84,990 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $69,798

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Fees Savings Natural Gas Savings
01 2.8114: Change rate schedules or other changes in utility service $43,338 - - $43,338 -
02 2.2511: Insulate bare equipment $14,251 $5,900 - - $14,251
-
MMBtu
03 2.4239: Eliminate or reduce compressed air usage $10,446 $890 $10,446
101,414
kWh
- -
04 2.2511: Insulate bare equipment $6,308 $6,013 - - $6,308
-
MMBtu
05 2.1233: Analyze flue gas for proper air/fuel ratio $4,439 $1,000 - - $4,439
-
MMBtu
06 2.2449: Recover heat from exhausted steam, hot air or hot water $2,752 $3,415 - - $2,752
-
MMBtu
07 2.5123: Reduce fluid flow rates $1,434 $2,200 - - $1,434
-
MMBtu
08 2.7142: Utilize higher efficiency lamps and/or ballasts $913 $600 $913
8,867
kWh
- -
09 2.2414: Use waste heat from hot flue gases to preheat $560 $1,815 - - $560
-
MMBtu
10 2.7134: Use photocell controls $549 $190 $549
5,331
kWh
- -
TOTAL RECOMMENDED $84,990 $22,023 $11,908
115,612
kWh
$43,338 $29,744
-
MMBtu
TOTAL IMPLEMENTED $69,798 $13,703 $1,462
14,198
kWh
$43,338 $24,998
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Fees Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs