Assessment Year | 2007 |
---|---|
Principal Product | vacuum thermoformed returnable packaging |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 60 |
Plant Area |
99,700
ft2
|
Annual Production | 10,000,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $266,939 | 3,444,793 |
kWh
|
$0.077 |
Electricity Demand | $26,287 | 13,781 |
kW-mo/yr
|
$1.91 |
Electricity Fees | $1,098 | - |
|
- |
Natural Gas | $192,949 | 19,283 |
MMBtu
|
$10.01 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $67,012 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $52,359 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $24,281 | $50,000 |
$17,320
203,765
kWh
|
- |
$6,961
-
MMBtu
|
|
02 | 2.2511: Insulate bare equipment | $14,750 | $1,970 |
$14,750
173,485
kWh
|
- | - | |
03 | 2.4239: Eliminate or reduce compressed air usage | $9,819 | $1,700 | - | - |
$9,819
-
MMBtu
|
|
04 | 2.2511: Insulate bare equipment | $9,662 | $6,000 |
$6,892
81,079
kWh
|
- |
$2,770
-
MMBtu
|
|
05 | 2.7135: Install occupancy sensors | $3,666 | $828 |
$3,666
47,309
kWh
|
- | - | |
06 | 2.7111: Reduce illumination to minimum necessary levels | $3,456 | $100 |
$3,300
42,558
kWh
|
$156
-
kW-mo/yr
|
- | |
07 | 2.4221: Install compressor air intakes in coolest locations | $1,378 | $410 | - | - |
$1,378
-
MMBtu
|
|
TOTAL RECOMMENDED | $67,012 | $61,008 |
$45,928
548,196
kWh
|
$156
-
kW-mo/yr
|
$20,928
-
MMBtu
|
||
TOTAL IMPLEMENTED | $52,359 | $58,798 |
$42,628
505,638
kWh
|
- |
$9,731
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs