| Assessment Year | 2005 |
|---|---|
| Principal Product | Corrugated Packaging |
| NAICS | 322211: Corrugated and Solid Fiber Box Manufacturing |
| SIC | 2653: Corrugated and Solid Fiber Boxes |
| Sales Range | $10 M to 50M |
| # of Employees | 140 |
| Plant Area |
312,550
ft2
|
| Annual Production | 650,000
thousand feet
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $254,278 | 5,985,779 |
kWh
|
$0.042 |
| Electricity Demand | $77,319 | 14,174 |
kW-mo/yr
|
$5.45 |
| Electricity Fees | $1,874 | - |
|
- |
| Natural Gas | $301,912 | 59,813 |
MMBtu
|
$5.05 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $268,460 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $34,442 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat | $193,508 | $1,140,000 |
$331,968
5,928,000
kWh
|
$62,130
-
kW-mo/yr
|
$(-200,590.0)
-
MMBtu
|
|
| 02 | 2.7243: Improve air circulation with destratification fans / other methods | $18,025 | $12,250 | - | - |
$18,025
-
MMBtu
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15,372 | $25,936 |
$12,330
290,254
kWh
|
$3,042
-
kW-mo/yr
|
- | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $15,025 | $1,800 |
$12,052
283,704
kWh
|
$2,973
-
kW-mo/yr
|
- | |
| 05 | 2.2437: Recover waste heat from equipment | $7,898 | $500 | - | - |
$7,898
-
MMBtu
|
|
| 06 | 2.7314: Reduce ventilation air | $7,113 | $5,492 | - | - |
$7,113
-
MMBtu
|
|
| 07 | 2.2426: Use waste heat from flue gases to heat space conditioning air | $4,883 | $3,000 | - | - |
$4,883
-
MMBtu
|
|
| 08 | 2.7229: Air condition only space necessary | $4,727 | $50 | - | - |
$4,727
-
MMBtu
|
|
| 09 | 2.4239: Eliminate or reduce compressed air usage | $1,909 | $1,000 |
$1,531
36,040
kWh
|
$378
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $268,460 | $1,190,028 |
$357,881
6,537,998
kWh
|
$68,523
-
kW-mo/yr
|
$(-157,944.0)
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $34,442 | $6,350 |
$13,583
319,744
kWh
|
$3,351
-
kW-mo/yr
|
$17,508
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs