Assessment Year | 2004 |
---|---|
Principal Product | Hardening of Automotive Fasteners |
NAICS | 332812: Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers |
SIC | 3328: |
Sales Range | $1 M to 5M |
# of Employees | 13 |
Plant Area |
65,000
ft2
|
Annual Production | 10,000,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $10,273 | 568,960 |
kWh
|
$0.018 |
Electricity Demand | $14,234 | 1,261 |
kW-mo/yr
|
$11.29 |
Electricity Fees | $891 | - |
|
- |
Natural Gas | $310,199 | 36,976 |
MMBtu
|
$8.39 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $16,047 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,888 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.2414: Use waste heat from hot flue gases to preheat | $12,159 | $14,530 |
$(-82.0)
(-4,476)
kWh
|
$(-101.0)
-
kW-mo/yr
|
$12,342
-
MMBtu
|
|
02 | 2.2425: Use flue gases to heat process or service water | $3,888 | $840 | - | - |
$3,888
-
MMBtu
|
|
TOTAL RECOMMENDED | $16,047 | $15,370 |
$(-82.0)
(-4,476)
kWh
|
$(-101.0)
-
kW-mo/yr
|
$16,230
-
MMBtu
|
||
TOTAL IMPLEMENTED | $3,888 | $840 | - | - |
$3,888
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs