Assessment Year | 2004 |
---|---|
Principal Product | Stampings and Welded Assemblies |
NAICS | 336370: Motor Vehicle Metal Stamping |
SIC | 3465: Automotive Stampings |
Sales Range | $10 M to 50M |
# of Employees | 115 |
Plant Area |
125,000
ft2
|
Annual Production | 50,000,000
pieces
|
Production Hrs. Annual | 5,760
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $214,684 | 4,903,506 |
kWh
|
$0.044 |
Electricity Demand | $27,304 | 6,595 |
kW-mo/yr
|
$4.14 |
Natural Gas | $161,937 | 22,327 |
MMBtu
|
$7.25 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $69,379 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $29,426 | $500 | - | - |
$29,426
-
MMBtu
|
|
02 | 2.2414: Use waste heat from hot flue gases to preheat | $15,300 | $15,300 | - | - |
$15,300
-
MMBtu
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,545 | $1,275 |
$5,621
107,166
kWh
|
$924
-
kW-mo/yr
|
- | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,828 | $900 |
$4,146
79,055
kWh
|
$682
-
kW-mo/yr
|
- | |
05 | 2.7135: Install occupancy sensors | $4,117 | $7,220 |
$4,117
79,170
kWh
|
- | - | |
06 | 2.4239: Eliminate or reduce compressed air usage | $3,963 | $2,000 |
$3,403
64,888
kWh
|
$560
-
kW-mo/yr
|
- | |
07 | 2.7135: Install occupancy sensors | $2,720 | $5,925 |
$2,720
53,325
kWh
|
- | - | |
08 | 2.2437: Recover waste heat from equipment | $2,480 | $500 | - | - |
$2,480
-
MMBtu
|
|
TOTAL RECOMMENDED | $69,379 | $33,620 |
$20,007
383,604
kWh
|
$2,166
-
kW-mo/yr
|
$47,206
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs