Assessment Year 2001
Principal Product Molten Aluminum
NAICS
n/a
SIC 3365: Aluminum Foundries
Sales Range $10
M
to 50
M
# of Employees 20
Plant Area 100,000
ft2
Annual Production 480,000,000
lb
Production Hrs. Annual 8,736
hrs
Location (State) Ohio

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $292,604 17,052,000
kWh
Electricity Demand $332,335 2,442
kW-mo/yr
Electricity Fees $50,504 -
Natural Gas $6,073,900 1,101,716
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $322,300 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Natural Gas Savings
01 2.2414: Use waste heat from hot flue gases to preheat $154,000 $154,000 $154,000
-
MMBtu
02 2.2414: Use waste heat from hot flue gases to preheat $166,000 $437,500 $166,000
-
MMBtu
03 2.2414: Use waste heat from hot flue gases to preheat $2,300 $5,000 $2,300
-
MMBtu
TOTAL RECOMMENDED $322,300 $596,500 $322,300
-
MMBtu
TOTAL IMPLEMENTED - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs