| Assessment Year | 2001 |
|---|---|
| Principal Product | Cold formed steel |
| NAICS |
n/a
|
| SIC | 3316: Cold-Rolled Steel Sheet, Strip, and Bars |
| Sales Range | $10 M to 50M |
| # of Employees | 79 |
| Plant Area |
75,000
ft2
|
| Annual Production | 30,000,000
lb
|
| Production Hrs. Annual | 5,460
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $235,572 | 6,553,107 |
kWh
|
$0.036 |
| Electricity Demand | $214,178 | 22,320 |
kW-mo/yr
|
$9.60 |
| Electricity Fees | $16,636 | - |
|
- |
| Natural Gas | $45,911 | 9,088 |
MMBtu
|
$5.05 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $169,468 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Other Liquid (non-haz) Savings | One-time Revenue or Avoided Cost Savings | Primary Product Savings | Increase in Production Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,736 | $5,155 |
$1,030
28,608
kWh
|
$706
-
kW-mo/yr
|
- | - | - | - | - | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,606 | $900 |
$1,708
47,433
kWh
|
$898
-
kW-mo/yr
|
- | - | - | - | - | |
| 03 | 3.3122: Use filtration, centrifuging to remove contaminants | $19,450 | $15,600 | - | - | - |
$19,450
-
gal
|
- | - | - | |
| 04 | 4.641: Eliminate shutdowns of controls due to overheating | $90,700 | $25,200 | - | - | - | - | $74,800 | - | $15,900 | |
| 05 | 4.652: Replace existing equipment with more suitable substitutes | $37,925 | $132,000 | - | - | - | - | - | $37,925 | - | |
| 06 | 4.611: Begin a practice of predictive / preventative maintenance | $2,888 | $4,500 | - | - | - | - | - | $2,888 | - | |
| 07 | 2.3212: Optimize plant power factor | $14,163 | $22,163 | - | - | $14,163 | - | - | - | - | |
| TOTAL RECOMMENDED | $169,468 | $205,518 |
$2,738
76,041
kWh
|
$1,604
-
kW-mo/yr
|
$14,163 |
$19,450
-
gal
|
$74,800 | $40,813 | $15,900 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Other Liquid (non-haz) Savings | One-time Revenue or Avoided Cost Savings | Primary Product Savings | Increase in Production Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs