Assessment Year | 2001 |
---|---|
Principal Product | Foundry Equipment |
NAICS |
n/a
|
SIC | 3297: Nonclay Refractories |
Sales Range | $1 M to 5M |
# of Employees | 48 |
Plant Area |
34,000
ft2
|
Annual Production | 5,525
ton
|
Production Hrs. Annual | 4,500
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $30,195 | 451,641 |
kWh
|
$0.067 |
Electricity Demand | $14,750 | 1,764 |
kW-mo/yr
|
$8.36 |
Electricity Fees | $1,159 | - |
|
- |
Natural Gas | $8,175 | 1,566 |
MMBtu
|
$5.22 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $63,240 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $63,240 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,540 | $750 |
$610
18,000
kWh
|
$930
-
kW-mo/yr
|
- | - | - | |
02 | 2.7243: Improve air circulation with destratification fans / other methods | $1,120 | $2,100 | - | - |
$1,120
-
MMBtu
|
- | - | |
03 | 2.8121: Apply for tax-free status for energy purchases | $6,580 | $950 | - | - | - | $6,580 | - | |
04 | 4.652: Replace existing equipment with more suitable substitutes | $54,000 | $16,000 | - | - | - | - | $54,000 | |
TOTAL RECOMMENDED | $63,240 | $19,800 |
$610
18,000
kWh
|
$930
-
kW-mo/yr
|
$1,120
-
MMBtu
|
$6,580 | $54,000 | ||
TOTAL IMPLEMENTED | $63,240 | $19,800 |
$610
18,000
kWh
|
$930
-
kW-mo/yr
|
$1,120
-
MMBtu
|
$6,580 | $54,000 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs