| Assessment Year | 2000 |
|---|---|
| Principal Product | Brass Castings |
| NAICS |
n/a
|
| SIC | 3366: Copper Foundries |
| Sales Range | $1 M to 5M |
| # of Employees | 28 |
| Plant Area |
11,000
ft2
|
| Annual Production | 780
ton
|
| Production Hrs. Annual | 2,431
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $65,607 | 732,415 |
kWh
|
$0.090 |
| Electricity Fees | $17,770 | - |
|
- |
| Natural Gas | $21,880 | 4,422 |
MMBtu
|
$4.95 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $20,554 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $14,353 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7135: Install occupancy sensors | $821 | $1,000 |
$821
7,327
kWh
|
- | - | - | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $9,562 | $1,200 |
$9,562
66,823
kWh
|
- | - | - | |
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,550 | $100 |
$1,550
13,482
kWh
|
- | - | - | |
| 04 | 2.2437: Recover waste heat from equipment | $791 | $500 | - | - |
$791
-
MMBtu
|
- | |
| 05 | 2.2437: Recover waste heat from equipment | $2,330 | $1,000 | - | - |
$2,330
-
MMBtu
|
- | |
| 06 | 4.122: Develop standard procedures to improve internal yields | $4,000 | $250 | - | $4,000 | - | - | |
| 07 | 2.8121: Apply for tax-free status for energy purchases | $1,500 | $3,000 | - | - | - | $1,500 | |
| TOTAL RECOMMENDED | $20,554 | $7,050 |
$11,933
87,632
kWh
|
$4,000 |
$3,121
-
MMBtu
|
$1,500 | ||
| TOTAL IMPLEMENTED | $14,353 | $1,950 |
$9,562
66,823
kWh
|
$4,000 |
$791
-
MMBtu
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs