Assessment Year | 1999 |
---|---|
Principal Product | Open-Die Steel Forgings |
NAICS |
n/a
|
SIC | 3426: |
Sales Range | $5 M to 10M |
# of Employees | 45 |
Plant Area |
94,500
ft2
|
Annual Production | 10,000,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $78,902 | 2,378,077 |
kWh
|
$0.033 |
Electricity Demand | $133,670 | 7,860 |
kW-mo/yr
|
$17.01 |
Electricity Fees | $8,710 | - |
|
- |
Natural Gas | $401,348 | 106,191 |
MMBtu
|
$3.78 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $63,661 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $11,391 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,707 | $9,821 |
$4,781
179,953
kWh
|
$4,926
-
kW-mo/yr
|
- | - | - | |
02 | 2.7229: Air condition only space necessary | $1,684 | $400 |
$1,684
170,574
kWh
|
- | - | - | - | |
03 | 2.1135: Repair furnaces and oven doors so that they seal efficiently | $1,436 | $600 | - | - |
$1,436
-
MMBtu
|
- | - | |
04 | 3.4114: Replace city water with recycled water via cooling tower | $2,058 | $2,250 | - | - | - |
$2,058
-
Tgal
|
- | |
05 | 4.811: Demolish old building to reduce tax and insurance bills | $48,776 | $103,584 | - | - | - | - | $48,776 | |
TOTAL RECOMMENDED | $63,661 | $116,655 |
$6,465
350,527
kWh
|
$4,926
-
kW-mo/yr
|
$1,436
-
MMBtu
|
$2,058
-
Tgal
|
$48,776 | ||
TOTAL IMPLEMENTED | $11,391 | $10,221 |
$6,465
350,527
kWh
|
$4,926
-
kW-mo/yr
|
- | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs