Assessment Year | 1999 |
---|---|
Principal Product | Baked Graphite Seals |
NAICS |
n/a
|
SIC | 3624: Carbon and Graphite Products |
Sales Range | $5 M to 10M |
# of Employees | 100 |
Plant Area |
60,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $143,865 | 4,288,394 |
kWh
|
$0.034 |
Electricity Demand | $77,713 | 9,060 |
kW-mo/yr
|
$8.58 |
Electricity Fees | $21,206 | - |
|
- |
Natural Gas | $308,434 | 94,036 |
MMBtu
|
$3.28 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $191,367 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings | By-product Production Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,119 | $13,195 |
$5,470
140,973
kWh
|
$1,649
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $21,707 | $23,612 |
$10,990
313,892
kWh
|
- | - | $10,717 | - | - | |
03 | 2.1224: Replace boiler | $78,528 | $13,800 | - | - |
$528
-
MMBtu
|
- | $78,000 | - | |
04 | 2.2437: Recover waste heat from equipment | $24,159 | $17,000 | - | - |
$24,159
-
MMBtu
|
- | - | - | |
05 | 4.122: Develop standard procedures to improve internal yields | $56,391 | $122,400 | - | - | - | - | - | $56,391 | |
06 | 4.514: Re-arrange equipment layout to reduce handling costs | $3,463 | $19,860 | - | - | - | $3,463 | - | - | |
TOTAL RECOMMENDED | $191,367 | $209,867 |
$16,460
454,865
kWh
|
$1,649
-
kW-mo/yr
|
$24,687
-
MMBtu
|
$14,180 | $78,000 | $56,391 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings | By-product Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs