Assessment Year | 1997 |
---|---|
Principal Product | Plastic Bottles and Blow Molded Parts |
NAICS |
n/a
|
SIC | 3098: |
Sales Range | $1 M to 5M |
# of Employees | 45 |
Plant Area |
51,500
ft2
|
Annual Production | 2,000,000
lb
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $39,936 | 1,181,125 |
kWh
|
$0.034 |
Electricity Demand | $65,175 | 3,924 |
kW-mo/yr
|
$16.61 |
Electricity Fees | $1,450 | - |
|
- |
LPG | $16,511 | 1,830 |
MMBtu
|
$9.02 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $45,748 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,363 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $2,091 | $2,882 |
$1,070
36,049
kWh
|
$1,021
-
kW-mo/yr
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,272 | $9,062 |
$1,699
57,444
kWh
|
$1,573
-
kW-mo/yr
|
- | |
03 | 2.4322: Use or replace with energy efficient substitutes | $12,065 | $36,247 |
$12,065
402,110
kWh
|
- | - | |
04 | 3.1162: Use less wasteful packaging | $4,000 | - | - | - |
$4,000
-
lb
|
|
05 | 3.1191: Change procedures / equipment / operating conditions | $24,320 | $24 | - | - |
$24,320
-
lb
|
|
TOTAL RECOMMENDED | $45,748 | $48,215 |
$14,834
495,603
kWh
|
$2,594
-
kW-mo/yr
|
$28,320
-
lb
|
||
TOTAL IMPLEMENTED | $5,363 | $11,944 |
$2,769
93,493
kWh
|
$2,594
-
kW-mo/yr
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs