Assessment Year | 1997 |
---|---|
Principal Product | Airline Meals/Beverages |
NAICS |
n/a
|
SIC | 2099: Food Preparations, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 585 |
Plant Area |
20,000
ft2
|
Annual Production | 6,570,000
pieces
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $133,349 | 5,443,728 |
kWh
|
$0.024 |
Electricity Demand | $142,985 | 9,228 |
kW-mo/yr
|
$15.49 |
Electricity Fees | $5,220 | - |
|
- |
Natural Gas | $145,437 | 34,060 |
MMBtu
|
$4.27 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $132,711 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $120,892 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $5,892 | $5,190 |
$3,502
118,699
kWh
|
$2,390
-
kW-mo/yr
|
- | - | - | |
02 | 2.2414: Use waste heat from hot flue gases to preheat | $5,427 | $3,920 | - | - |
$5,427
-
MMBtu
|
- | - | |
03 | 2.2437: Recover waste heat from equipment | $5,039 | $6,000 | - | - |
$5,039
-
MMBtu
|
- | - | |
04 | 3.5212: Regrind, reuse, or sell scrap plastic parts | $1,353 | $3,800 | - | - | - |
$1,353
-
lb
|
- | |
05 | 4.514: Re-arrange equipment layout to reduce handling costs | $115,000 | $2,400 | - | - | - | - | $115,000 | |
TOTAL RECOMMENDED | $132,711 | $21,310 |
$3,502
118,699
kWh
|
$2,390
-
kW-mo/yr
|
$10,466
-
MMBtu
|
$1,353
-
lb
|
$115,000 | ||
TOTAL IMPLEMENTED | $120,892 | $7,590 |
$3,502
118,699
kWh
|
$2,390
-
kW-mo/yr
|
- | - | $115,000 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs