| Assessment Year | 1996 |
|---|---|
| Principal Product | Automotive Bright Plating |
| NAICS |
n/a
|
| SIC | 3471: Electroplating, Plating, Polishing, Anodizing, and Coloring |
| Sales Range | $10 M to 50M |
| # of Employees | 95 |
| Plant Area |
65,000
ft2
|
| Annual Production | 892,500
pieces
|
| Production Hrs. Annual | 6,120
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $209,161 | 8,764,068 |
kWh
|
$0.024 |
| Electricity Demand | $162,935 | 9,384 |
kW-mo/yr
|
$17.36 |
| Electricity Fees | $(-144,405.0) | - |
|
- |
| Natural Gas | $121,068 | 72,697 |
MMBtu
|
$1.67 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $48,427 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $293 | $300 |
$151
4,982
kWh
|
$142
-
kW-mo/yr
|
- | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,223 | $5,402 |
$3,516
61,254
kWh
|
$1,707
-
kW-mo/yr
|
- | - | |
| 03 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $464 | $990 | - | - |
$464
-
MMBtu
|
- | |
| 04 | 3.5311: Recover and reuse waste material | $42,447 | $990 | - | - | - |
$42,447
-
Tgal
|
|
| TOTAL RECOMMENDED | $48,427 | $7,682 |
$3,667
66,236
kWh
|
$1,849
-
kW-mo/yr
|
$464
-
MMBtu
|
$42,447
-
Tgal
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs