Assessment Year | 2008 |
---|---|
Principal Product | Hydraulic Tubular Handling Equipment |
NAICS | 333132: Oil and Gas Field Machinery and Equipment Manufacturing |
SIC | 3533: Oil and Gas Field Machinery and Equipment |
Sales Range | $10 M to 50M |
# of Employees | 128 |
Plant Area |
44,000
ft2
|
Annual Production | 600,000
pieces
|
Production Hrs. Annual | 4,200
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $104,441 | 1,174,011 |
kWh
|
$0.089 |
Electricity Fees | $3,391 | - |
|
- |
Natural Gas | $16,638 | 1,150 |
MMBtu
|
$14.47 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $39,047 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,885 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $15,764 | $1,710 |
$15,275
170,705
kWh
|
$489 | - | - | |
02 | 2.7224: Reduce space conditioning during non-working hours | $8,261 | $1,320 |
$8,005
89,981
kWh
|
$256 | - | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,846 | $3,025 |
$6,634
74,574
kWh
|
$212 | - | - | |
04 | 4.611: Begin a practice of predictive / preventative maintenance | $5,230 | $1,470 |
$3,614
40,622
kWh
|
$116 | - | $1,500 | |
05 | 2.7111: Reduce illumination to minimum necessary levels | $1,925 | $348 |
$1,865
20,960
kWh
|
$60 | - | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $853 | $490 |
$415
4,660
kWh
|
$13 | $425 | - | |
07 | 2.6211: Conserve energy by efficient use of vending machines | $168 | $160 |
$155
1,747
kWh
|
$13 | - | - | |
TOTAL RECOMMENDED | $39,047 | $8,523 |
$35,963
403,249
kWh
|
$1,159 | $425 | $1,500 | ||
TOTAL IMPLEMENTED | $17,885 | $5,183 |
$16,919
190,175
kWh
|
$541 | $425 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs