| Assessment Year | 1996 |
|---|---|
| Principal Product | Cold drawn steel bars |
| NAICS |
n/a
|
| SIC | 3316: Cold-Rolled Steel Sheet, Strip, and Bars |
| Sales Range | $10 M to 50M |
| # of Employees | 129 |
| Plant Area |
139,520
ft2
|
| Annual Production | 55,481
ton
|
| Production Hrs. Annual | 4,576
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $117,752 | 4,253,810 |
kWh
|
$0.028 |
| Electricity Demand | $251,831 | 15,228 |
kW-mo/yr
|
$16.54 |
| Electricity Fees | $6,442 | - |
|
- |
| Natural Gas | $52,467 | 12,948 |
MMBtu
|
$4.05 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $71,620 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $39,128 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $1,018 | $1,248 |
$619
7,034
kWh
|
$399
-
kW-mo/yr
|
- | - | - | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $14,049 | $62,773 |
$9,688
110,199
kWh
|
$4,361
-
kW-mo/yr
|
- | - | - | - | |
| 03 | 2.3212: Optimize plant power factor | $1,261 | $1,830 | - | - | $1,261 | - | - | - | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,635 | $223 |
$2,196
24,912
kWh
|
$1,439
-
kW-mo/yr
|
- | - | - | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $586 | $300 |
$411
4,689
kWh
|
$175
-
kW-mo/yr
|
- | - | - | - | |
| 06 | 2.7243: Improve air circulation with destratification fans / other methods | $27,309 | $18,500 | - | - | - |
$27,309
-
MMBtu
|
- | - | |
| 07 | 3.7198: Reduce / eliminate use of disposable product | $22,800 | $42,500 | - | - | - | - |
$800
-
lb
|
$22,000 | |
| 08 | 3.7131: Use a rag recycle service | $962 | $78 | - | - | - | - |
$170
-
lb
|
$792 | |
| TOTAL RECOMMENDED | $71,620 | $127,452 |
$12,914
146,834
kWh
|
$6,374
-
kW-mo/yr
|
$1,261 |
$27,309
-
MMBtu
|
$970
-
lb
|
$22,792 | ||
| TOTAL IMPLEMENTED | $39,128 | $108,351 |
$10,307
117,233
kWh
|
$4,760
-
kW-mo/yr
|
$1,261 | - |
$800
-
lb
|
$22,000 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs