ITAC Assessment: UM0040
ITAC logo
ITAC Assessment: UM0040
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1995
Principal Product Coat fasteners
NAICS
n/a
SIC 3452: Bolts, Nuts, Screws, Rivets, and Washers
Sales Range $5
M
to 10
M
# of Employees 45
Plant Area 43,000
ft2
Annual Production 240,000,000
lb
Production Hrs. Annual 4,800
hrs
Location (State) Michigan

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $66,761 657,386
kWh
Natural Gas $12,723 3,007
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $12,003 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Administrative Changes Savings
01 2.4133: Use most efficient type of electric motors $600 $996 n/a $600
5,862
kWh
-
02 2.7142: Utilize higher efficiency lamps and/or ballasts $4,515 $13,295 n/a $4,515
44,256
kWh
-
03 2.8114: Change rate schedules or other changes in utility service $6,888 $250 n/a - $6,888
TOTAL RECOMMENDED $12,003 $14,541 $5,115
50,118
kWh
$6,888
TOTAL IMPLEMENTED - - - -