| Assessment Year | 1995 |
|---|---|
| Principal Product | Metal heat Treating |
| NAICS |
n/a
|
| SIC | 3398: Metal Heat Treating |
| Sales Range | $1 M to 5M |
| # of Employees | 44 |
| Plant Area |
10,000
ft2
|
| Annual Production | 265,000
lb
|
| Production Hrs. Annual | 7,488
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $73,484 | 1,320,926 |
kWh
|
$0.056 |
| Natural Gas | $147,064 | 45,431 |
MMBtu
|
$3.24 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $6,643 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,965 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $1,253 | $655 |
$1,253
22,274
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $555 | $1,453 |
$555
9,965
kWh
|
- | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,157 | $350 |
$1,157
20,516
kWh
|
- | |
| 04 | 2.2427: Use waste heat from hot flue gases to preheat incoming fluids | $3,678 | $1,832 | - |
$3,678
-
MMBtu
|
|
| TOTAL RECOMMENDED | $6,643 | $4,290 |
$2,965
52,755
kWh
|
$3,678
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $2,965 | $2,458 |
$2,965
52,755
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs