| Assessment Year | 1995 |
|---|---|
| Principal Product | Processing of steel bars |
| NAICS |
n/a
|
| SIC | 3399: Primary Metal Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 15 |
| Plant Area |
52,000
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 7,200
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $64,197 | 591,442 |
kWh
|
$0.11 |
| Natural Gas | $195,980 | 60,972 |
MMBtu
|
$3.21 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $46,251 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,209 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $1,209 | $1,167 |
$1,209
11,137
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,758 | $5,594 |
$2,758
25,498
kWh
|
- | |
| 03 | 2.3212: Optimize plant power factor | $1,047 | $2,160 |
$1,047
-
kWh
|
- | |
| 04 | 2.1122: Re-size charging openings or add a movable door on equipment | $28,057 | $1,600 | - |
$28,057
-
MMBtu
|
|
| 05 | 2.2414: Use waste heat from hot flue gases to preheat | $13,180 | $8,000 | - |
$13,180
-
MMBtu
|
|
| TOTAL RECOMMENDED | $46,251 | $18,521 |
$5,014
36,635
kWh
|
$41,237
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $1,209 | $1,167 |
$1,209
11,137
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs