| Assessment Year | 2026 |
|---|---|
| Principal Product | Wooden Staves and Headings |
| NAICS | 321920: Wood Container and Pallet Manufacturing |
| SIC | 2449: Wood Containers, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 250 |
| Plant Area |
275,830
ft2
|
| Annual Production | 550,000
units
|
| Production Hrs. Annual | 2,080
hrs
|
| Location (State) | Kentucky |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $233,093 | 5,841,250 |
kWh
|
$0.040 |
| Electricity Demand | $521,760 | 20,018 |
kW-mo/yr
|
$26.06 |
| Electricity Fees | $102,420 | - |
|
- |
| Natural Gas | $113,113 | 13,939 |
MMBtu
|
$8.11 |
| Other Gas | $9,322 | 1 |
MMBtu
|
$9,322.00 |
| Other Energy | $24,135 | 1,222 |
MMBtu
|
$19.75 |
| TOTAL YEARLY COSTS | $1,003,843 | |||
| RECOMMENDED SAVINGS* | $155,647 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,696 | $1,080 |
$1,696
42,501
kWh
|
- | - | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,332 | - |
$4,332
108,574
kWh
|
- | - | |
| 03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $19,244 | $32,250 |
$19,244
482,315
kWh
|
- | - | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,472 | $855 |
$3,472
87,033
kWh
|
- | - | |
| 05 | 2.6212: Turn off equipment during breaks, reduce operating time | $34,484 | - |
$34,484
864,269
kWh
|
- | - | |
| 06 | 2.3212: Optimize plant power factor | $70,132 | $11,173 | - | - | $70,132 | |
| 07 | 2.9114: Use solar heat to make electricty | $22,287 | $267,913 |
$10,207
255,790
kWh
|
$12,080
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $155,647 | $313,271 |
$73,435
1,840,482
kWh
|
$12,080
-
kW-mo/yr
|
$70,132 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs