| Assessment Year | 2026 |
|---|---|
| Principal Product | Peanut Butter |
| NAICS | 311911: Roasted Nuts and Peanut Butter Manufacturing |
| SIC | 2099: Food Preparations, Not Elsewhere Classified |
| Sales Range | $100 M to 500M |
| # of Employees | 300 |
| Plant Area |
162,000
ft2
|
| Annual Production | 170,000,000
lb
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Kentucky |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $560,476 | 17,217,000 |
kWh
|
$0.033 |
| Electricity Demand | $692,696 | 33,354 |
kW-mo/yr
|
$20.77 |
| Electricity Fees | $114,542 | - |
|
- |
| Natural Gas | $356,112 | 67,725 |
MMBtu
|
$5.26 |
| Other Gas | $35,505 | 1 |
MMBtu
|
$35,505.00 |
| TOTAL YEARLY COSTS | $1,759,331 | |||
| RECOMMENDED SAVINGS* | $123,620 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7135: Install occupancy sensors | $269 | $106 |
$269
8,278
kWh
|
- | - | |
| 02 | 2.7243: Improve air circulation with destratification fans / other methods | $6,794 | $10,000 |
$6,794
208,710
kWh
|
- | - | |
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,621 | - |
$4,621
135,435
kWh
|
- | - | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,937 | $945 |
$1,937
59,432
kWh
|
- | - | |
| 05 | 2.2692: Use outside cold water source as a supply of cooling water | $43,299 | $98,575 |
$18,208
558,514
kWh
|
$25,091
-
kW-mo/yr
|
- | |
| 06 | 2.2437: Recover waste heat from equipment | $35,971 | $32,500 | - | - |
$35,971
-
MMBtu
|
|
| 07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,278 | $2,850 |
$1,278
39,212
kWh
|
- | - | |
| 08 | 2.9114: Use solar heat to make electricty | $29,450 | $438,603 |
$13,694
420,666
kWh
|
$15,756
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $123,620 | $583,579 |
$46,802
1,430,247
kWh
|
$40,847
-
kW-mo/yr
|
$35,971
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs