| Assessment Year | 2026 |
|---|---|
| Principal Product | Aluminum Powder |
| NAICS | 331314: Secondary Smelting and Alloying of Aluminum |
| SIC | 3341: Secondary Smelting and Refining of Nonferrous Metals |
| Sales Range | $10 M to 50M |
| # of Employees | 69 |
| Plant Area |
274,429
ft2
|
| Annual Production | 12,618,810
lb
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Kentucky |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $367,058 | 11,314,800 |
kWh
|
$0.032 |
| Electricity Demand | $452,406 | 21,949 |
kW-mo/yr
|
$20.61 |
| Electricity Fees | $23,476 | - |
|
- |
| Natural Gas | $31,966 | 3,564 |
MMBtu
|
$8.97 |
| Other Energy | $9,780 | 1 |
MMBtu
|
$9,780.00 |
| TOTAL YEARLY COSTS | $884,686 | |||
| RECOMMENDED SAVINGS* | $61,407 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,768 | $3,073 |
$4,685
144,603
kWh
|
$4,083
-
kW-mo/yr
|
- | |
| 02 | 2.7135: Install occupancy sensors | $1,639 | $4,686 |
$1,639
50,596
kWh
|
- | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,787 | $3,450 |
$3,787
116,894
kWh
|
- | - | |
| 04 | 2.2692: Use outside cold water source as a supply of cooling water | $8,862 | $43,234 |
$2,531
78,016
kWh
|
$6,331
-
kW-mo/yr
|
- | |
| 05 | 2.9114: Use solar heat to make electricty | $20,448 | $314,019 |
$9,252
285,209
kWh
|
$11,196
-
kW-mo/yr
|
- | |
| 06 | 2.2437: Recover waste heat from equipment | $17,903 | $50,000 | - | - |
$17,903
-
MMBtu
|
|
| TOTAL RECOMMENDED | $61,407 | $418,462 |
$21,894
675,318
kWh
|
$21,610
-
kW-mo/yr
|
$17,903
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs