| Assessment Year | 2026 |
|---|---|
| Principal Product | Nanowire Materials |
| NAICS | 325998: All Other Miscellaneous Chemical Product and Preparation Manufacturing |
| SIC | 2899: Chemicals and Chemical Preparations, Not Elsewhere Classified |
| Sales Range | less than $500 k |
| # of Employees | 6 |
| Plant Area |
18,990
ft2
|
| Annual Production | 25
ton
|
| Production Hrs. Annual | 2,080
hrs
|
| Location (State) | Kentucky |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $21,013 | 330,796 |
kWh
|
$0.064 |
| Electricity Demand | $43,554 | 1,640 |
kW-mo/yr
|
$26.56 |
| Electricity Fees | $6,563 | - |
|
- |
| Natural Gas | $8,547 | 2,019 |
MMBtu
|
$4.23 |
| Other Gas | $12,238 | 1 |
MMBtu
|
$12,238.00 |
| TOTAL YEARLY COSTS | $91,915 | |||
| RECOMMENDED SAVINGS* | $39,152 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.1122: Re-size charging openings or add a movable door on equipment | $286 | $500 |
$286
4,396
kWh
|
- | - | |
| 02 | 2.2511: Insulate bare equipment | $2,011 | $1,050 |
$2,011
31,670
kWh
|
- | - | |
| 03 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $6,056 | - | - |
$6,056
-
kW-mo/yr
|
- | |
| 04 | 2.3212: Optimize plant power factor | $5,290 | $26,000 | - | - | $5,290 | |
| 05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $9,804 | $6,617 |
$9,804
154,246
kWh
|
- | - | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,253 | $315 |
$1,253
19,728
kWh
|
- | - | |
| 07 | 2.7135: Install occupancy sensors | $102 | $386 |
$102
1,604
kWh
|
- | - | |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,565 | $11,013 |
$736
11,583
kWh
|
$1,829
-
kW-mo/yr
|
- | |
| 09 | 2.9114: Use solar heat to make electricty | $11,785 | $116,051 |
$6,453
101,591
kWh
|
$5,332
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $39,152 | $161,932 |
$20,645
324,818
kWh
|
$13,217
-
kW-mo/yr
|
$5,290 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs