Assessment Year 2026
Principal Product Distilled spirits
NAICS 312140: Distilleries
SIC 2085: Distilled and Blended Liquors
Sales Range $10
M
to 50
M
# of Employees 150
Plant Area 776,000
ft2
Annual Production 6,000
Tgal
Production Hrs. Annual 7,728
hrs
Location (State) Kentucky

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $479,869 17,083,800
kWh
Electricity Demand $761,236 33,833
kW-mo/yr
Electricity Fees $114,368 -
Natural Gas $1,097,037 279,013
MMBtu
Other Gas $363,298 1
MMBtu
Waste Disposal Costs
Water Usage $44,877 6,629
Tgal
TOTAL YEARLY COSTS $2,860,685
RECOMMENDED SAVINGS* $304,280 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Usage Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,992 $1,155 $1,992
70,882
kWh
- - -
02 2.2437: Recover waste heat from equipment $5,474 $13,000 - - $5,474
-
MMBtu
-
03 2.2136: Install / repair insulation on steam lines $5,070 $3,340 - - $5,070
-
MMBtu
-
04 2.2121: Increase amount of condensate returned $28,057 $40,600 - - $16,201
-
MMBtu
$11,856
-
Tgal
05 2.9114: Use solar heat to make electricty $26,708 $193,418 $15,417
548,417
kWh
$11,291
-
kW-mo/yr
- -
06 2.2692: Use outside cold water source as a supply of cooling water $236,979 $474,400 $236,979
8,433,301
kWh
- - -
TOTAL RECOMMENDED $304,280 $725,913 $254,388
9,052,600
kWh
$11,291
-
kW-mo/yr
$26,745
-
MMBtu
$11,856
-
Tgal
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Usage Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs