| Assessment Year | 2025 |
|---|---|
| Principal Product | Jewelry Repair |
| NAICS | 811490: Other Personal and Household Goods Repair and Maintenance |
| SIC | 7631: Watch, Clock, and Jewelry Repair |
| Sales Range | $10 M to 50M |
| # of Employees | 280 |
| Plant Area |
50,000
ft2
|
| Annual Production | 500,000
units
|
| Production Hrs. Annual | 3,264
hrs
|
| Location (State) | Kentucky |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $83,660 | 1,114,080 |
kWh
|
$0.075 |
| Electricity Demand | $19,109 | 3,014 |
kW-mo/yr
|
$6.34 |
| Electricity Fees | $25,119 | - |
|
- |
| Natural Gas | $11,184 | 884 |
MMBtu
|
$12.65 |
| TOTAL YEARLY COSTS | $139,072 | |||
| RECOMMENDED SAVINGS* | $23,782 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7144: Install spectral reflectors / delamp | $461 | - |
$352
4,700
kWh
|
$109
-
kW-mo/yr
|
|
| 02 | 2.7135: Install occupancy sensors | $179 | $196 |
$179
2,385
kWh
|
- | |
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $126 | - |
$126
1,672
kWh
|
- | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $916 | $540 |
$916
12,197
kWh
|
- | |
| 05 | 2.9114: Use solar heat to make electricty | $22,100 | $183,557 |
$19,081
254,105
kWh
|
$3,019
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $23,782 | $184,293 |
$20,654
275,059
kWh
|
$3,128
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs