Assessment Year | 2024 |
---|---|
Principal Product | Actuators |
NAICS | 335312: Motor and Generator Manufacturing |
SIC | 3621: Motors and Generators |
Sales Range | $100 M to 500M |
# of Employees | 350 |
Plant Area |
220,000
ft2
|
Annual Production | 3,500,000
units
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Kentucky |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $98,363 | 2,834,000 |
kWh
|
$0.035 |
Electricity Demand | $188,715 | 7,515 |
kW-mo/yr
|
$25.11 |
Electricity Fees | $27,131 | - |
|
- |
Natural Gas | $32,177 | 3,413 |
MMBtu
|
$9.43 |
TOTAL YEARLY COSTS | $346,386 | |||
RECOMMENDED SAVINGS* | $212,341 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $5,637 | $7,818 | - | - | $5,637 | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,855 | $3,045 |
$6,855
176,214
kWh
|
- | - | - | |
03 | 2.9114: Use solar heat to make electricty | $121,785 | $1,075,553 |
$51,713
1,543,672
kWh
|
$70,072
-
kW-mo/yr
|
- | - | |
04 | 2.7224: Reduce space conditioning during non-working hours | $3,526 | $1,500 |
$993
28,373
kWh
|
- | - |
$2,533
-
MMBtu
|
|
05 | 2.7243: Improve air circulation with destratification fans / other methods | $3,205 | $15,000 |
$3,205
91,561
kWh
|
- | - | - | |
06 | 2.2692: Use outside cold water source as a supply of cooling water | $71,333 | $21,308 |
$1,232
35,203
kWh
|
$70,101
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $212,341 | $1,124,224 |
$63,998
1,875,023
kWh
|
$140,173
-
kW-mo/yr
|
$5,637 |
$2,533
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs