Assessment Year | 2024 |
---|---|
Principal Product | Miscellaneous Machined Parts |
NAICS | 332710: Machine Shops |
SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 40 |
Plant Area |
66,000
ft2
|
Annual Production | 46,800
units
|
Production Hrs. Annual | 2,960
hrs
|
Location (State) | Kentucky |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $96,130 | 1,140,480 |
kWh
|
$0.084 |
Electricity Demand | $36,944 | 3,725 |
kW-mo/yr
|
$9.92 |
Electricity Fees | $12,576 | - |
|
- |
Natural Gas | $16,925 | 2,410 |
MMBtu
|
$7.02 |
TOTAL YEARLY COSTS | $162,575 | |||
RECOMMENDED SAVINGS* | $82,262 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $12,828 | $3,060 |
$12,828
152,193
kWh
|
- | - | |
02 | 2.9114: Use solar heat to make electricty | $52,875 | $349,289 |
$43,886
520,658
kWh
|
$8,989
-
kW-mo/yr
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,202 | $4,083 |
$7,028
83,367
kWh
|
$3,174
-
kW-mo/yr
|
- | |
04 | 2.7221: Lower temperature during the winter season and vice-versa | $6,357 | $1,200 |
$3,782
44,864
kWh
|
- |
$2,575
-
MMBtu
|
|
TOTAL RECOMMENDED | $82,262 | $357,632 |
$67,524
801,082
kWh
|
$12,163
-
kW-mo/yr
|
$2,575
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs