ITAC Assessment: UL2402
ITAC logo
ITAC Assessment: UL2402
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2024
Principal Product Hard Hats and Safety Equipment
NAICS 339113: Surgical Appliance and Supplies Manufacturing
SIC 3842: Orthopedic, Prosthetic, and Surgical Appliances and Supplies
Sales Range $50
M
to 100
M
# of Employees 250
Plant Area 138,000
ft2
Annual Production 1,400,000
units
Production Hrs. Annual 3,060
hrs
Location (State) Kentucky

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $174,770 5,223,000
kWh
Electricity Demand $253,344 13,345
kW-mo/yr
Electricity Fees $69,099 -
Natural Gas $38,250 3,822
MMBtu
TOTAL YEARLY COSTS $535,463
RECOMMENDED SAVINGS* $334,219 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.7144: Install spectral reflectors / delamp $1,664 $1,130 $449
13,410
kWh
$1,215
-
kW-mo/yr
02 2.7111: Reduce illumination to minimum necessary levels $2,889 - $823
24,598
kWh
$2,066
-
kW-mo/yr
03 2.4231: Reduce the pressure of compressed air to the minimum required $677 - $677
20,223
kWh
-
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $5,801 $3,150 $5,801
173,362
kWh
-
05 2.2692: Use outside cold water source as a supply of cooling water $176,163 $90,792 $98,162
2,933,572
kWh
$78,001
-
kW-mo/yr
06 2.9114: Use solar heat to make electricty $147,025 $1,560,993 $70,153
2,094,129
kWh
$76,872
-
kW-mo/yr
TOTAL RECOMMENDED $334,219 $1,656,065 $176,065
5,259,294
kWh
$158,154
-
kW-mo/yr
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs