Assessment Year | 2024 |
---|---|
Principal Product | Commercial Kitchen and Cooking Equipment |
NAICS | 333310: Commercial and Service Industry Machinery Manufacturing |
SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
81,000
ft2
|
Annual Production | 6,025
units
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Kentucky |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $72,069 | 1,850,520 |
kWh
|
$0.039 |
Electricity Demand | $137,921 | 5,335 |
kW-mo/yr
|
$25.85 |
Electricity Fees | $42,029 | - |
|
- |
Natural Gas | $24,769 | 1,744 |
MMBtu
|
$14.20 |
TOTAL YEARLY COSTS | $276,788 | |||
RECOMMENDED SAVINGS* | $80,791 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $54,908 | $450,549 |
$24,690
634,716
kWh
|
$30,218
-
kW-mo/yr
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,727 | $3,600 |
$1,727
44,402
kWh
|
- | - | - | |
03 | 2.3212: Optimize plant power factor | $17,320 | $13,000 | - | - | $17,320 | - | |
04 | 2.7224: Reduce space conditioning during non-working hours | $1,830 | - |
$684
17,551
kWh
|
- | - |
$1,146
-
MMBtu
|
|
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,468 | $1,000 |
$1,189
30,567
kWh
|
$2,279
-
kW-mo/yr
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,347 | $2,270 |
$413
10,628
kWh
|
$933
-
kW-mo/yr
|
- | - | |
07 | 2.7135: Install occupancy sensors | $191 | $504 |
$191
4,918
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $80,791 | $470,923 |
$28,895
742,782
kWh
|
$33,430
-
kW-mo/yr
|
$17,320 |
$1,146
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs