Assessment Year | 2024 |
---|---|
Principal Product | Repair of industrial machines |
NAICS | 332710: Machine Shops |
SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 230 |
Plant Area |
80,000
ft2
|
Annual Production | 10,000
units
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Kentucky |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $74,417 | 2,515,800 |
kWh
|
$0.030 |
Electricity Demand | $155,187 | 5,687 |
kW-mo/yr
|
$27.29 |
Electricity Fees | $37,168 | - |
|
- |
Natural Gas | $79,113 | 6,065 |
MMBtu
|
$13.04 |
TOTAL YEARLY COSTS | $345,885 | |||
RECOMMENDED SAVINGS* | $125,348 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,826 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $29,804 | $13,936 | - | - | $29,804 | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,821 | $13,461 |
$1,261
42,064
kWh
|
$1,560
-
kW-mo/yr
|
- | - | |
03 | 2.7243: Improve air circulation with destratification fans / other methods | $20,576 | $15,000 | - | - | - |
$20,576
-
MMBtu
|
|
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,358 | - |
$1,358
45,267
kWh
|
- | - | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $5,061 | $4,320 |
$5,061
168,688
kWh
|
- | - | - | |
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,398 | $6,825 |
$3,398
114,856
kWh
|
- | - | - | |
07 | 2.9114: Use solar heat to make electricty | $54,095 | $476,338 |
$20,369
688,593
kWh
|
$33,726
-
kW-mo/yr
|
- | - | |
08 | 2.2692: Use outside cold water source as a supply of cooling water | $2,765 | $100 |
$2,765
92,154
kWh
|
- | - | - | |
09 | 2.2437: Recover waste heat from equipment | $5,470 | $15,600 | - | - | - |
$5,470
-
MMBtu
|
|
TOTAL RECOMMENDED | $125,348 | $545,580 |
$34,212
1,151,622
kWh
|
$35,286
-
kW-mo/yr
|
$29,804 |
$26,046
-
MMBtu
|
||
TOTAL IMPLEMENTED | $7,826 | $4,420 |
$7,826
260,842
kWh
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs