Assessment Year | 2023 |
---|---|
Principal Product | carpet and other underlayment materials |
NAICS | 336390: Other Motor Vehicle Parts Manufacturing |
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $50 M to 100M |
# of Employees | 350 |
Plant Area |
387,000
ft2
|
Annual Production | 5,950,225
units
|
Production Hrs. Annual | 7,200
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,186,831 | 27,925,435 |
kWh
|
$0.043 |
Electricity Demand | $382,667 | 67,468 |
kW-mo/yr
|
$5.67 |
Electricity Fees | $396,082 | - |
|
- |
Natural Gas | $785,394 | 303,884 |
MMBtu
|
$2.58 |
TOTAL YEARLY COSTS | $2,750,974 | |||
RECOMMENDED SAVINGS* | $128,193 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $104,242 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,769 | $4,795 |
$4,753
111,826
kWh
|
$1,016
-
kW-mo/yr
|
- | - | |
02 | 2.4131: Size electric motors for peak operating efficiency | $4,739 | $7,251 |
$931
21,915
kWh
|
$3,808
-
kW-mo/yr
|
- | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,426 | - |
$2,601
60,487
kWh
|
$825
-
kW-mo/yr
|
- | - | |
04 | 2.3212: Optimize plant power factor | $32,626 | $94,199 | - | - | $32,626 | - | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $5,163 | $19,500 |
$4,224
99,393
kWh
|
$939
-
kW-mo/yr
|
- | - | |
06 | 2.2414: Use waste heat from hot flue gases to preheat | $7,602 | $50,000 | - | - | - |
$7,602
-
MMBtu
|
|
07 | 2.9114: Use solar heat to make electricty | $6,919 | $102,018 |
$5,418
127,476
kWh
|
$1,501
-
kW-mo/yr
|
- | - | |
08 | 2.2692: Use outside cold water source as a supply of cooling water | $6,524 | $25,900 |
$6,524
153,501
kWh
|
- | - | - | |
09 | 2.7313: Recycle air for heating, ventilation and air conditioning | $33,279 | - |
$33,279
783,376
kWh
|
- | - | - | |
10 | 2.7313: Recycle air for heating, ventilation and air conditioning | $22,146 | $30,000 | - | - | - |
$22,146
-
MMBtu
|
|
TOTAL RECOMMENDED | $128,193 | $333,663 |
$57,730
1,357,974
kWh
|
$8,089
-
kW-mo/yr
|
$32,626 |
$29,748
-
MMBtu
|
||
TOTAL IMPLEMENTED | $104,242 | $193,699 |
$40,104
943,256
kWh
|
$1,764
-
kW-mo/yr
|
$32,626 |
$29,748
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs