| Assessment Year | 2000 |
|---|---|
| Principal Product | Denatured Alcohol and Chafing Dish Fuel |
| NAICS |
n/a
|
| SIC | 2869: Industrial Organic Chemicals, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 85 |
| Plant Area |
66,000
ft2
|
| Annual Production | 185,760
Tgal
|
| Production Hrs. Annual | 10,320
hrs
|
| Location (State) | Kentucky |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $53,539 | 1,276,671 |
kWh
|
$0.042 |
| Electricity Demand | $23,020 | 4,826 |
kW-mo/yr
|
$4.77 |
| Natural Gas | $7,424 | 1,299 |
MMBtu
|
$5.72 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $8,319 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Water Consumption Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,068 | $5,019 |
$301
7,327
kWh
|
$141
-
kW-mo/yr
|
- | - | $626 | |
| 02 | 3.4157: Replace water cooling on processes with air cooling | $7,251 | $4,000 | - | - |
$4,227
-
Tgal
|
$3,024
-
Tgal
|
- | |
| TOTAL RECOMMENDED | $8,319 | $9,019 |
$301
7,327
kWh
|
$141
-
kW-mo/yr
|
$4,227
-
Tgal
|
$3,024
-
Tgal
|
$626 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs