Assessment Year 2024
Principal Product Movie Picture & Video Production
NAICS 512110: Motion Picture and Video Production
SIC 7812: Motion Picture and Video Tape Production
Sales Range $100
M
to 500
M
# of Employees 1,200
Plant Area 2,787,840
ft2
Annual Production 100
units
Production Hrs. Annual 8,736
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $4,424,249 16,545,399
kWh
Electricity Demand $293,809 64,431
kW-mo/yr
Natural Gas $5,926 1,022
MMBtu
TOTAL YEARLY COSTS $4,723,984
RECOMMENDED SAVINGS* $1,741,018 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Ancillary Material Cost Savings
01 2.9114: Use solar heat to make electricty $249,555 $400,591 $232,745
870,400
kWh
$16,810
-
kW-mo/yr
- -
02 2.3132: Recharge batteries on during off-peak demand periods $2,912 - - $2,912
-
kW-mo/yr
- -
03 2.7134: Use photocell controls $7,731 $3,463 $7,469
27,935
kWh
$206
-
kW-mo/yr
- $56
04 2.7135: Install occupancy sensors $7,224 $4,470 $7,030
26,292
kWh
$194
-
kW-mo/yr
- -
05 2.6242: Minimize operation of equipment maintained in standby condition $1,431,356 $2,700 $1,410,364
5,274,360
kWh
$20,992
-
kW-mo/yr
- -
06 2.7233: Use properly designed and sized hvac equipment $39,277 $137,300 $36,859
137,843
kWh
$2,418
-
kW-mo/yr
- -
07 2.1221: Replace obsolete burners with more efficient ones $2,963 - - - $2,963
-
MMBtu
-
TOTAL RECOMMENDED $1,741,018 $548,524 $1,694,467
6,336,830
kWh
$43,532
-
kW-mo/yr
$2,963
-
MMBtu
$56
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs