| Assessment Year | 2024 |
|---|---|
| Principal Product | Movie Picture & Video Production |
| NAICS | 512110: Motion Picture and Video Production |
| SIC | 7812: Motion Picture and Video Tape Production |
| Sales Range | $100 M to 500M |
| # of Employees | 1,200 |
| Plant Area |
2,787,840
ft2
|
| Annual Production | 100
units
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $4,424,249 | 16,545,399 |
kWh
|
$0.27 |
| Electricity Demand | $293,809 | 64,431 |
kW-mo/yr
|
$4.56 |
| Natural Gas | $5,926 | 1,022 |
MMBtu
|
$5.80 |
| TOTAL YEARLY COSTS | $4,723,984 | |||
| RECOMMENDED SAVINGS* | $1,741,018 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.9114: Use solar heat to make electricty | $249,555 | $400,591 |
$232,745
870,400
kWh
|
$16,810
-
kW-mo/yr
|
- | - | |
| 02 | 2.3132: Recharge batteries on during off-peak demand periods | $2,912 | - | - |
$2,912
-
kW-mo/yr
|
- | - | |
| 03 | 2.7134: Use photocell controls | $7,731 | $3,463 |
$7,469
27,935
kWh
|
$206
-
kW-mo/yr
|
- | $56 | |
| 04 | 2.7135: Install occupancy sensors | $7,224 | $4,470 |
$7,030
26,292
kWh
|
$194
-
kW-mo/yr
|
- | - | |
| 05 | 2.6242: Minimize operation of equipment maintained in standby condition | $1,431,356 | $2,700 |
$1,410,364
5,274,360
kWh
|
$20,992
-
kW-mo/yr
|
- | - | |
| 06 | 2.7233: Use properly designed and sized hvac equipment | $39,277 | $137,300 |
$36,859
137,843
kWh
|
$2,418
-
kW-mo/yr
|
- | - | |
| 07 | 2.1221: Replace obsolete burners with more efficient ones | $2,963 | - | - | - |
$2,963
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $1,741,018 | $548,524 |
$1,694,467
6,336,830
kWh
|
$43,532
-
kW-mo/yr
|
$2,963
-
MMBtu
|
$56 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs