| Assessment Year | 2000 |
|---|---|
| Principal Product | Powder Coated Parts |
| NAICS |
n/a
|
| SIC | 3479: Coating, Engraving, and Allied Services, Not Elsewhere Classified |
| Sales Range | $5 M to 10M |
| # of Employees | 90 |
| Plant Area |
40,000
ft2
|
| Annual Production | 32,400,000
pieces
|
| Production Hrs. Annual | 7,488
hrs
|
| Location (State) | Kentucky |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $118,497 | 2,899,766 |
kWh
|
$0.041 |
| Electricity Demand | $38,523 | 8,076 |
kW-mo/yr
|
$4.77 |
| Natural Gas | $35,514 | 5,437 |
MMBtu
|
$6.53 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $25,351 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,646 | $9,827 | n/a |
$1,323
32,532
kWh
|
$323
-
kW-mo/yr
|
- | - |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,135 | $20 | n/a |
$1,718
41,911
kWh
|
$417
-
kW-mo/yr
|
- | - |
| 03 | 3.5316: Contract a wood pallet recycling company | $19,623 | - | n/a | - | - |
$19,623
-
lb
|
- |
| 04 | 4.421: Modify current incentive program | $1,947 | $60 | n/a | - | - | - | $1,947 |
| TOTAL RECOMMENDED | $25,351 | $9,907 |
$3,041
74,443
kWh
|
$740
-
kW-mo/yr
|
$19,623
-
lb
|
$1,947 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs