Assessment Year | 2000 |
---|---|
Principal Product | Unglazed ceramic tile |
NAICS |
n/a
|
SIC | 3253: Ceramic Wall and Floor Tile |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
200,000
ft2
|
Annual Production | 15,000
thousand feet
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Kentucky |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $204,298 | 11,666,178 |
kWh
|
$0.018 |
Electricity Demand | $177,658 | 19,600 |
kW-mo/yr
|
$9.06 |
Natural Gas | $970,122 | 399,700 |
MMBtu
|
$2.43 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $123,006 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $24,726 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $24,726 | $16,605 |
$24,726
-
kW-mo/yr
|
- | - | |
02 | 2.2511: Insulate bare equipment | $34,297 | $19,628 | - |
$34,297
-
MMBtu
|
- | |
03 | 4.445: Install equipment to move product | $57,400 | $38,400 | - | - | $57,400 | |
04 | 4.126: Install sensors to detect defects | $6,583 | $30,160 | - | - | $6,583 | |
TOTAL RECOMMENDED | $123,006 | $104,793 |
$24,726
-
kW-mo/yr
|
$34,297
-
MMBtu
|
$63,983 | ||
TOTAL IMPLEMENTED | $24,726 | $16,605 |
$24,726
-
kW-mo/yr
|
- | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs