Assessment Year | 1999 |
---|---|
Principal Product | Waste water and ethylene glycol |
NAICS |
n/a
|
SIC | 2911: Petroleum Refining |
Sales Range | $10 M to 50M |
# of Employees | 35 |
Plant Area |
56,000
ft2
|
Annual Production | 3,300
Tgal
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $61,499 | 2,717,175 |
kWh
|
$0.023 |
Electricity Demand | $91,105 | 8,467 |
kW-mo/yr
|
$10.76 |
Natural Gas | $249,893 | 67,437 |
MMBtu
|
$3.71 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $23,696 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,509 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $18,187 | $21,040 | $18,187 | - | |
02 | 2.2136: Install / repair insulation on steam lines | $5,509 | $2,875 | - |
$5,509
-
MMBtu
|
|
TOTAL RECOMMENDED | $23,696 | $23,915 | $18,187 |
$5,509
-
MMBtu
|
||
TOTAL IMPLEMENTED | $5,509 | $2,875 | - |
$5,509
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs