| Assessment Year | 1999 |
|---|---|
| Principal Product | Carbon and stainless steel fabricated products |
| NAICS |
n/a
|
| SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 100 |
| Plant Area |
75,500
ft2
|
| Annual Production | 4,465
ton
|
| Production Hrs. Annual | 2,040
hrs
|
| Location (State) | Kentucky |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $32,770 | 1,127,784 |
kWh
|
$0.029 |
| Electricity Demand | $16,337 | 3,661 |
kW-mo/yr
|
$4.46 |
| Natural Gas | $20,302 | 3,858 |
MMBtu
|
$5.26 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $178,305 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $72,554 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Solid Waste (non-haz) Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,326 | $20 |
$694
24,033
kWh
|
$632
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,708 | $8,456 |
$1,424
48,945
kWh
|
$1,284
-
kW-mo/yr
|
- | - | - | |
| 03 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $16,091 | $8,165 | - | - | - |
$16,091
-
lb
|
- | |
| 04 | 3.5217: Reuse / recycle/ sell paper products | $200 | $150 | - | - | - |
$200
-
lb
|
- | |
| 05 | 3.7214: Reduce or eliminate waste | $15,966 | $1,448 | - | - |
$15,966
-
gal
|
- | - | |
| 06 | 3.2121: Convert to electrostatic powder coating | $32,230 | $13,000 | - | - |
$32,230
-
gal
|
- | - | |
| 07 | 3.7214: Reduce or eliminate waste | $55,904 | $285,000 | - | - |
$55,904
-
gal
|
- | - | |
| 08 | 4.445: Install equipment to move product | $53,880 | - | - | - | - | - | $53,880 | |
| TOTAL RECOMMENDED | $178,305 | $316,239 |
$2,118
72,978
kWh
|
$1,916
-
kW-mo/yr
|
$104,100
-
gal
|
$16,291
-
lb
|
$53,880 | ||
| TOTAL IMPLEMENTED | $72,554 | $9,904 |
$1,424
48,945
kWh
|
$1,284
-
kW-mo/yr
|
$15,966
-
gal
|
- | $53,880 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Solid Waste (non-haz) Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs