Assessment Year | 1997 |
---|---|
Principal Product | Corrugated Packaging |
NAICS |
n/a
|
SIC | 2653: Corrugated and Solid Fiber Boxes |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
150,000
ft2
|
Annual Production | 218,000
thousand feet
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Kentucky |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $64,424 | 2,604,338 |
kWh
|
$0.025 |
Electricity Demand | $66,190 | 6,909 |
kW-mo/yr
|
$9.58 |
Natural Gas | $15,909 | 3,139 |
MMBtu
|
$5.07 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $34,508 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $943 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $266 | $7,360 |
$126
4,982
kWh
|
$140
-
kW-mo/yr
|
- | - | - | |
02 | 2.3212: Optimize plant power factor | $6,333 | $6,499 | - | - | $6,333 | - | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $677 | $20 |
$320
12,603
kWh
|
$357
-
kW-mo/yr
|
- | - | - | |
04 | 2.7261: Install timers and/or thermostats | $1,320 | $2,600 | - | - | - |
$1,320
-
MMBtu
|
- | |
05 | 3.5313: Increase amount of waste recovered for resale | $23,580 | $4,040 | - | - | - | - |
$23,580
-
lb
|
|
06 | 3.6123: Burn wood by-products for heat | $625 | - | - | - | - | - |
$625
-
lb
|
|
07 | 3.5313: Increase amount of waste recovered for resale | $1,707 | - | - | - | - | - |
$1,707
-
lb
|
|
TOTAL RECOMMENDED | $34,508 | $20,519 |
$446
17,585
kWh
|
$497
-
kW-mo/yr
|
$6,333 |
$1,320
-
MMBtu
|
$25,912
-
lb
|
||
TOTAL IMPLEMENTED | $943 | $7,380 |
$446
17,585
kWh
|
$497
-
kW-mo/yr
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs