| Assessment Year | 1996 |
|---|---|
| Principal Product | Organic and Inorganic Pigments |
| NAICS |
n/a
|
| SIC | 2865: Cyclic Organic Crudes and Intermediates, and Organic Dyes and Pigments |
| Sales Range | $50 M to 100M |
| # of Employees | 210 |
| Plant Area |
n/a
|
| Annual Production | 17,000,000
lb
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Kentucky |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $298,496 | 12,221,278 |
kWh
|
$0.024 |
| Electricity Demand | $150,892 | 22,656 |
kW-mo/yr
|
$6.66 |
| Natural Gas | $3,662 | 3,657 |
MMBtu
|
$1.00 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $254,295 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $600 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $195 | $500 | - | - |
$195
-
MMBtu
|
- | - | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $990 | $3,186 |
$697
28,429
kWh
|
$293
-
kW-mo/yr
|
- | - | - | - | |
| 03 | 2.4133: Use most efficient type of electric motors | $600 | $9,340 |
$434
17,878
kWh
|
$166
-
kW-mo/yr
|
- | - | - | - | |
| 04 | 3.7221: Improve process control to prevent spills of material | $199,480 | $26,580 | - | - | - | - | - | $199,480 | |
| 05 | 3.5311: Recover and reuse waste material | $16,140 | $9,500 | - | - | - |
$16,140
-
lb
|
- | - | |
| 06 | 3.7134: Wash and reuse rags on-site | $1,860 | $4,500 | - | - | - | - | $1,860 | - | |
| 07 | 3.6192: Use a less expensive method of waste removal | $22,850 | - | - | - | - |
$22,850
-
lb
|
- | - | |
| 08 | 3.5217: Reuse / recycle/ sell paper products | $12,180 | - | - | - | - |
$12,180
-
lb
|
- | - | |
| TOTAL RECOMMENDED | $254,295 | $53,606 |
$1,131
46,307
kWh
|
$459
-
kW-mo/yr
|
$195
-
MMBtu
|
$51,170
-
lb
|
$1,860 | $199,480 | ||
| TOTAL IMPLEMENTED | $600 | $9,340 |
$434
17,878
kWh
|
$166
-
kW-mo/yr
|
- | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs