| Assessment Year | 1994 |
|---|---|
| Principal Product | Fireproof Cabinets |
| NAICS |
n/a
|
| SIC | 3275: Gypsum Products |
| Sales Range | $10 M to 50M |
| # of Employees | 340 |
| Plant Area |
108,000
ft2
|
| Annual Production | 50,000
pieces
|
| Production Hrs. Annual | 5,880
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $163,435 | 3,677,315 |
kWh
|
$0.044 |
| Natural Gas | $207,312 | 56,837 |
MMBtu
|
$3.65 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $23,964 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $19,814 | $13,206 | n/a |
$19,814
-
kWh
|
- |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,382 | $9,632 | n/a |
$3,382
76,202
kWh
|
- |
| 03 | 2.4133: Use most efficient type of electric motors | $525 | $860 | n/a |
$525
11,723
kWh
|
- |
| 04 | 2.2511: Insulate bare equipment | $243 | $420 | n/a | - |
$243
-
MMBtu
|
| TOTAL RECOMMENDED | $23,964 | $24,118 |
$23,721
87,925
kWh
|
$243
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs