Assessment Year | 1994 |
---|---|
Principal Product | Fireproof Cabinets |
NAICS |
n/a
|
SIC | 3275: Gypsum Products |
Sales Range | $10 M to 50M |
# of Employees | 340 |
Plant Area |
108,000
ft2
|
Annual Production | 50,000
pieces
|
Production Hrs. Annual | 5,880
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $163,435 | 3,677,315 |
kWh
|
$0.044 |
Natural Gas | $207,312 | 56,837 |
MMBtu
|
$3.65 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $23,964 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $19,814 | $13,206 | n/a |
$19,814
-
kWh
|
- |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,382 | $9,632 | n/a |
$3,382
76,202
kWh
|
- |
03 | 2.4133: Use most efficient type of electric motors | $525 | $860 | n/a |
$525
11,723
kWh
|
- |
04 | 2.2511: Insulate bare equipment | $243 | $420 | n/a | - |
$243
-
MMBtu
|
TOTAL RECOMMENDED | $23,964 | $24,118 |
$23,721
87,925
kWh
|
$243
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |