| Assessment Year | 2021 |
|---|---|
| Principal Product | potable drinking water |
| NAICS | 221310: Water Supply and Irrigation Systems |
| SIC | 4941: Water Supply |
| Sales Range | $1 M to 5M |
| # of Employees | 4 |
| Plant Area |
9,483
ft2
|
| Annual Production | 500,000
Tgal
|
| Production Hrs. Annual | 4,500
hrs
|
| Location (State) | Kentucky |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $100,288 | 1,588,000 |
kWh
|
$0.063 |
| Electricity Demand | $61,479 | 4,497 |
kW-mo/yr
|
$13.67 |
| Electricity Fees | $293 | - |
|
- |
| TOTAL YEARLY COSTS | $162,060 | |||
| RECOMMENDED SAVINGS* | $54,190 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $51,422 | - |
$28,456
451,690
kWh
|
$22,966
-
kW-mo/yr
|
|
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $54 | $63 |
$34
540
kWh
|
$20
-
kW-mo/yr
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,386 | $4,128 |
$1,828
29,017
kWh
|
$558
-
kW-mo/yr
|
|
| 04 | 2.7221: Lower temperature during the winter season and vice-versa | $328 | - |
$328
5,210
kWh
|
- | |
| TOTAL RECOMMENDED | $54,190 | $4,191 |
$30,646
486,457
kWh
|
$23,544
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs