| Assessment Year | 2019 |
|---|---|
| Principal Product | Direct Mail |
| NAICS | 323111: Commercial Printing (except Screen and Books) |
| SIC | 7331: Direct Mail Advertising Services |
| Sales Range | $10 M to 50M |
| # of Employees | 100 |
| Plant Area |
106,000
ft2
|
| Annual Production | 90,000,000
pieces
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $70,636 | 1,180,828 |
kWh
|
$0.060 | |
| Electricity Demand | $20,039 | 3,411 |
kW-mo/yr
|
$5.87 | |
| Electricity Fees | $23,629 | - |
|
- | |
| Natural Gas | $14,430 | 1,637 |
MMBtu
|
$8.81 | |
| Waste Disposal Costs | |||||
| Water Usage | $8,905 | 3,433 |
Tgal
|
$2.59 | |
| TOTAL YEARLY COSTS | $137,639 | ||||
| RECOMMENDED SAVINGS* | $25,228 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $515 | - |
$515
8,580
kWh
|
- | - | |
| 02 | 2.7224: Reduce space conditioning during non-working hours | $1,579 | - | - | - |
$1,579
-
MMBtu
|
|
| 03 | 2.7221: Lower temperature during the winter season and vice-versa | $1,341 | - | - | - |
$1,341
-
MMBtu
|
|
| 04 | 2.7135: Install occupancy sensors | $2,357 | $717 |
$2,357
39,277
kWh
|
- | - | |
| 05 | 2.7141: Lower light fixtures in high ceiling areas | $311 | $1,218 |
$262
4,368
kWh
|
$49
-
kW-mo/yr
|
- | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $451 | $486 |
$397
6,623
kWh
|
$54
-
kW-mo/yr
|
- | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,016 | $11,658 |
$8,217
136,955
kWh
|
$1,799
-
kW-mo/yr
|
- | |
| 08 | 2.7311: Ventilation system to shut off when room is not in use | $332 | - |
$279
4,655
kWh
|
$53
-
kW-mo/yr
|
- | |
| 09 | 2.4133: Use most efficient type of electric motors | $8,326 | $6,103 |
$7,009
116,813
kWh
|
$1,317
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $25,228 | $20,182 |
$19,036
317,271
kWh
|
$3,272
-
kW-mo/yr
|
$2,920
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs